A cascading failure is a failure in a system of interconnected parts in which the failure of a part can trigger the failure of successive parts. Such a failure may happen in many types of systems, including power transmission, computer networking, finance, human bodily systems, and bridges.
Cascading failures usually begin when one part of the system fails. When this happens, nearby nodes must then compensate for the failed component. This in turn overloads these nodes, causing them to fail as well, prompting additional nodes to fail one after another in a vicious circle.
Cascading Failure in Power
Transmission
Cascading failure is common in power grids when one of the elements fails (completely or partially) and shifts its load to nearby elements in the system. Those nearby elements are then pushed beyond their capacity so they become overloaded and shift their load onto other elements. Cascading failure is a common effect seen in high voltage systems, where a single point of failure (SPF) on a fully loaded or slightly overloaded system results in a sudden spike across all nodes of the system. This surge current can induce the already overloaded nodes into failure, setting off more overloads and thereby taking down the entire system in a very short time.
This failure process cascades through the elements of the system like a ripple on a pond and continues until substantially all of the elements in the system are compromised and/or the system becomes functionally disconnected from the source of its load. For example, under certain conditions a large power grid can collapse after the failure of a single transformer.
Monitoring the operation of a system, in real-time, and judicious disconnection of parts can help stop a cascade. Another common technique is to calculate a safety margin for the system by computer simulation of possible failures, to establish safe operating levels below which none of the calculated scenarios is predicted to cause cascading failure, and to identify the parts of the network which are most likely to cause cascading failures. One of the primary problems with preventing electrical grid failures is that the speed of the control signal is no faster than the speed of the propagating power overload, i.e. since both the control signal and the electrical power are moving at the same speed, it is not possible to isolate the outage by sending a warning ahead to isolate the element.
Cascading Failure in Computer
Networks
Cascading failures can also occur in computer networks (such as the Internet) in which network traffic is severely impaired or halted to or between larger sections of the network, caused by failing or disconnected hardware or software. In this context, the cascading failure is known by the term cascade failure. A cascade failure can affect large groups of people and systems.
The cause of a cascade failure is usually the overloading of a single, crucial router or node, which causes the node to go down, even briefly. It can also be caused by taking a node down for maintenance or upgrades. In either case, traffic is routed to or through another (alternative) path. This alternative path, as a result, becomes overloaded, causing it to go down, and so on. It will also affect systems which depend on the node for regular operation.
Symptoms
The symptoms of a cascade failure include: packet loss and high network latency, not just to single systems, but to whole sections of a network or the internet. The high latency and packet loss is caused by the nodes that fail to operate due to congestion collapse, which causes them to still be present in the network but without much or any useful communication going through them. As a result, routes can still be considered valid, without them actually providing communication.
If enough routes go down because of a cascade failure, a complete section of the network or internet can become unreachable. Although undesired, this can help speed up the recovery from this failure as connections will time out, and other nodes will give up trying to establish connections to the section(s) that have become cut off, decreasing load on the involved nodes.
A common occurrence during a cascade failure is a walking failure, where sections go down, causing the next section to fail, after which the first section comes back up. This ripple can make several passes through the same sections or connecting nodes before stability is restored.
History
Cascade failures are a relatively recent development, with the massive increase in traffic and the high interconnectivity between systems and networks. The term was first applied in this context in the late 1990s by a Dutch IT professional and has slowly become a relatively common term for this kind of large-scale failure.
Example
Network failures typically start when a single network node fails. Initially, the traffic that would normally go through the node is stopped. Systems and users get errors about not being able to reach hosts. Usually, the redundant systems of an ISP respond very quickly, choosing another path through a different backbone. The routing path through this alternative route is longer, with more hops and subsequently going through more systems that normally do not process the amount of traffic suddenly offered.
This can cause one or more systems along the alternative route to go down, creating similar problems of their own.
Also, related systems are affected in this case. As an example, DNS resolution might fail and what would normally cause systems to be interconnected, might break connections that are not even directly involved in the actual systems that went down. This, in turn, may cause seemingly unrelated nodes to develop problems, that can cause another cascade failure all on its own.
In December 2012, a partial loss (40%) of GMail service occurred globally, for 18 minutes. This loss of service was caused by a routine update of load balancing software which contained faulty logic—in this case, the error was caused by logic using an inappropriate all instead of the more appropriate some. The cascading error was fixed by fully updating a single node in the network instead of partially updating all nodes at one time.
Cascading Structural Failure
Certain
load-bearing structures with discrete structural components can be subject to
the "zipper effect", where the failure of a single structural member
increases the load on adjacent members. In the case of the Hyatt Regency
walkway collapse, a suspended walkway (which was already overstressed due to an
error in construction) failed when a single vertical suspension rod failed, overloading
the neighboring rods which failed sequentially (i.e. like a zipper). A bridge
that can have such a failure is called fracture critical, and numerous bridge
collapses have been caused by the failure of a single part. Properly designed
structures use an
adequate factor of safety and/or alternate load paths to prevent
this type of mechanical cascade failure.